ISO/IEC 17025:2017 Accredited  •  NIST-Traceable Calibration  •  In-Lab & Onsite Service  •  (334) 792-0113 ext. 1
ISO/IEC 17025:2017 Accredited NIST-Traceable Certificate Included In-Lab & Onsite Fast Turnaround

Relative Humidity Sensor Calibration Services

The wall-mounted sensor nobody touches is quietly deciding compliance every minute.

ACS Calibration delivers NIST-traceable, audit-ready relative humidity sensor calibration, available at the ACS central lab or directly on-site at facilities across the Southeast. Temperature from -196 °C to 420 °C, infrared to 500 °C, and humidity from 30 to 75 %RH are on our accredited scope, so ISO/IEC 17025 accredited certificates are available on request.

RH Sensor calibration service at ACS Calibration
Instrument Types

Temperature & Humidity Instruments We Calibrate

From cryogenic checks to furnace controllers — if it reads degrees or percent RH, we can almost certainly handle it.

Frequently serviced brands: Traceable (Control Company), Gemini Tinytag, T&D, MadgeTech, Fluke, ThermoWorks, LogTag, and ThermoPro — plus dozens more.

Accredited Temperature & Humidity Capability

These ranges appear on our PJLA scope of accreditation — verify it independently anytime. Thermocouple indication and control equipment (Types K, J, and T) is additionally covered from -200 °C to 1,370 °C. Instruments outside these ranges receive NIST-traceable calibration.

-196–420 °Ctemperature accredited
35–500 °Cinfrared accredited
30–75 %RHhumidity accredited
#98908PJLA accreditation
View Our Scope of Accreditation
ParameterAccredited Range
Temperature (measure)-196 °C – 420 °C
Temperature (source)-30 °C – 420 °C
Infrared thermometers35 °C – 500 °C
Relative humidity30 %RH – 75 %RH
Why It Matters

Fixed Sensors, Drifting Truth

RH transmitters bolted to walls and ducts feed building automation, cleanroom monitoring, and chamber control loops — and precisely because they’re installed and forgotten, their drift goes unchallenged. A capacitive element that’s aged a few percent doesn’t alarm; it just moves the whole room’s recorded history.

We calibrate RH sensors and transmitters across our accredited 30–75 %RH band against humidity references, verifying the sensor and its output signal, with as-found and as-left data that tells you exactly what the building system has been logging. Temperature elements in combined sensors are covered under the same accredited scope.

In-place calibration via onsite service keeps control loops live; swap-and-rotate programs work too. Pair with the loggers validating the same spaces and the chambers those sensors steer.

Deliverables

What You Get With Every Calibration

  • NIST-traceable calibration certificate with real measurement data — not just a pass/fail sticker
  • As-found and as-left readings, so drift is documented
  • ISO/IEC 17025 accredited certificate with reported uncertainty — on request
  • Calibration label with due date, plus a reminder before your next calibration is due
The ACS Difference

Why Companies Choose ACS for RH Sensor Calibration

NIST-Traceable, Accredited on Request

Every calibration is NIST-traceable with real measurement data. Temperature (-196 to 420 °C), infrared (35–500 °C), and humidity (30–75 %RH) are on our ISO/IEC 17025 accredited scope — accredited certificates available whenever your quality system requires them.

4–6 Business Day Typical Turnaround

Keep production moving. Most instruments are typically completed in 4 to 6 business days from arrival, with rush options available when a line is down.

Flexible Logistics

Mail your instruments in, or schedule onsite calibration and we come to your floor — serving Alabama, Florida, Georgia, Mississippi, Tennessee, South Carolina, and beyond.

How It Works

Calibration Without the Hassle

1. Ship It or Schedule Us

Send your instrument to our Dothan, AL laboratory — or book onsite service and we come to your facility.

2. NIST-Traceable Calibration

ASQ Certified Technicians calibrate your instrument against NIST-traceable reference standards — in our lab or at your facility.

3. Audit-Ready Certificate

Your instrument returns with a NIST-traceable certificate documenting as-found and as-left data. ISO/IEC 17025 accredited certificates available on request.

Need this calibrated?

Accredited, NIST-traceable, in-lab or onsite. Get pricing and turnaround fast.