ISO/IEC 17025:2017 Accredited  •  NIST-Traceable Calibration  •  In-Lab & Onsite Service  •  (334) 792-0113 ext. 1
ISO/IEC 17025:2017 Accredited NIST-Traceable Certificate Included In-Lab & Onsite Fast Turnaround

Dial Torque Wrench Calibration Services

A dial torque wrench doesn’t click — it shows you the number. Which means the number has to be right.

ACS Calibration delivers NIST-traceable, audit-ready dial torque wrench calibration, available at the ACS central lab or directly on-site at facilities across the Southeast. Dial torque wrenches fall squarely on our accredited torque scope, so ISO/IEC 17025 accredited certificates are available on request.

Dial Torque Wrench calibration service at ACS Calibration
Instrument Types

Torque & Force Tools We Calibrate

If it tightens, twists, pushes, or pulls, we can almost certainly handle it.

Frequently serviced brands: Snap-on, CDI Torque Products, Sturtevant Richmont, Tohnichi, Proto, Husky, Westward, Wiha, and GearWrench — plus dozens more.

Accredited Torque Capability

These ranges appear on our PJLA scope of accreditation — verify it independently anytime. Shown in inch-pound units with newton-meter (N·m) equivalents for metric tools. Instruments outside these ranges — up to 750 ft·lb — receive NIST-traceable calibration.

10–400in·lb accredited range
33–250ft·lb accredited range
≈1.1–339N·m equivalent span
#98908PJLA accreditation
View Our Scope of Accreditation
InstrumentAccredited Range
Torque wrenches10 in·lb – 400 in·lb
Torque wrenches33 ft·lb – 250 ft·lb
Torque transducers1 lbf·in – 100 lbf·in
Why It Matters

Why Dial Wrenches Earn Their Keep — and Their Calibration

A dial torque wrench reads out actual applied torque on a beam-driven dial instead of breaking at a preset — which is why inspectors and quality departments reach for them to audit joints, check residual torque, and troubleshoot fastening problems a click-type wrench would hide. Many carry a memory needle that captures peak torque on a single pull.

That visibility cuts both ways: a bent torsion beam, a sticky movement, or an abused memory needle skews every reading it will ever give you. We calibrate dial wrenches at multiple points across the working range in the direction of use, with as-found and as-left data recorded — so drift is documented, not discovered during an audit.

Dial wrenches from 10–400 in·lb and 33–250 ft·lb are covered by our accredited torque capability; tools outside those ranges receive NIST-traceable calibration with identical documentation. If your program also verifies tools against a bench reference, we calibrate torque meters and analyzers and torque screwdrivers too.

Deliverables

What You Get With Every Calibration

  • NIST-traceable calibration certificate with real measurement data — not just a pass/fail sticker
  • As-found and as-left readings, so drift is documented
  • ISO/IEC 17025 accredited certificate with reported uncertainty — on request
  • Calibration label with due date, plus a reminder before your next calibration is due
The ACS Difference

Why Companies Choose ACS for Dial Torque Wrench Calibration

NIST-Traceable, Accredited on Request

Every calibration is NIST-traceable with real measurement data. Dial torque wrenches are on our ISO/IEC 17025 accredited scope — accredited certificates available whenever your quality system requires them.

4–6 Business Day Typical Turnaround

Keep production moving. Most instruments are typically completed in 4 to 6 business days from arrival, with rush options available when a line is down.

Flexible Logistics

Mail your instruments in, or schedule onsite calibration and we come to your floor — serving Alabama, Florida, Georgia, Mississippi, Tennessee, South Carolina, and beyond.

How It Works

Calibration Without the Hassle

1. Ship It or Schedule Us

Send your instrument to our Dothan, AL laboratory — or book onsite service and we come to your facility.

2. NIST-Traceable Calibration

ASQ Certified Technicians calibrate your instrument against NIST-traceable reference standards — in our lab or at your facility.

3. Audit-Ready Certificate

Your instrument returns with a NIST-traceable certificate documenting as-found and as-left data. ISO/IEC 17025 accredited certificates available on request.

Need this calibrated?

Accredited, NIST-traceable, in-lab or onsite. Get pricing and turnaround fast.